How Long It Runs

How we calculate power station runtime

The formula

Runtime (hours) = battery capacity (Wh) × 85% ÷ load (W).

The 85% factor covers inverter and conversion losses on the AC outlets. It's an assumption, not a measurement; real efficiency varies by model and load.

Appliances that cycle on and off

Refrigerators and dehumidifiers don't run all the time. For these we use average draw from utility data. A refrigerator rated 225 W that runs about 288 hours a month averages 90 W.

Start-up surge

Motors need a short burst of power to start. We compare the appliance's start-up power with the station's continuous output and, if needed, its published surge rating.

If a motor's start-up power isn't published, we assume 3× its running power and hold the page for manual review.

Where the numbers come from

Station specs are read from each manufacturer's own product page. Each value carries a label: read from the official page, official page with conflicting figures, manufacturer listing, or third-party.

Appliance power comes from utility data (FirstEnergy), Honda's generator sizing table and manufacturers' own documents (Starlink, ResMed). Every page links its sources and the date we checked them.

What we don't do

We don't test power stations ourselves. These are calculated estimates; real runtime depends on temperature, battery age, settings and your exact appliance.